How do they get you off the operating table once surgery is over? The answer is a planned team manoeuvre rather than a lift: the patient is slid or glided across a low-friction surface onto a trolley or bed, with the airway protected and the lines secured. This guide describes the common methods, the equipment involved and how table choice influences safety for patients and staff.
The principle: slide, do not lift
Safe patient transfer on an operating table follows a simple rule: reduce the lifting and the friction. Moving an anaesthetised patient from table to trolley involves a dead weight that cannot assist, and manual lifting is a leading cause of musculoskeletal injury among nursing and theatre staff.
Teams therefore use lateral transfer aids that let the patient slide horizontally between two surfaces set at the same height, with the brakes on both.
Equipment for moving a patient to the operating table
The most common aid is a patient transfer board, a rigid low-friction board that bridges the gap between table and trolley. Flexible slide sheets and roller boards serve the same purpose, and air-assisted hover mats reduce effort further for heavier patients. Whichever you choose, it must be radiolucent if it stays under the patient during imaging, and it must be cleanable between cases.
Choose equipment to match your patients. For bariatric patients, use aids rated for the load and make sure enough staff are present. Always follow your hospital's manual handling policy.
- Rigid transfer board for stable lateral slides
- Slide sheets or roller boards for lighter transfers
- Air-assisted mats where heavier patients are common
- Straps and padding to protect limbs and lines
Steps and roles in a safe transfer
A typical sequence begins with a briefing. One person, usually the anaesthetist, controls the head and airway and calls the move. Other staff position themselves on both sides, drains, catheters and intravenous lines are checked, and the trolley is brought to the same height as the table, aligned and braked.
The patient is then moved on the call, while the team keeps the spine neutral and avoids dragging the skin. After the move, check lines, monitoring and pressure points, secure side rails and only then release the brakes. The sequence is the same when moving a patient to the operating table at the start of the case.
How the table and trolley design help
Table design shapes how hard a transfer is. A top that is at the same height as the trolley, firm locking and a low profile all help. Some day surgery units use an all-in-one solution: the Lojer Rapido is a hydraulic table-trolley for pre-induction, transport, operation and recovery, so the patient can stay on the same surface through the pathway.
Rapido has safety rails for transport, antistatic twin castors with central locking and a safe working load of 160 kg, with a height range of 650 to 1020 mm adjusted by foot pedals. This reduces the number of transfers, though your risk assessment decides when one is still needed.
Common transfer mistakes to avoid
Frequent errors include mismatched heights between table and trolley, unlocked brakes on one surface, pulling the patient by the limbs or sheet corners and leaving a catheter or line unsecured. Another is forgetting that a patient who has just been anaesthetised cannot protect their own joints.
Build a short checklist into the sign-out routine: heights matched, brakes on, lines checked, airway controlled, skin and pressure points inspected. Repeating it every case makes the safe method the habit.
Planning for your department
Write transfer procedures into your theatre policy, train every new team member and audit practice. Check that doors, lifts and corridors suit the equipment. For related guidance, read our article on operating table safety straps.
If you are reviewing equipment for a new or refurbished suite, ask Beckfinity's specialists to advise through our contact page.
Frequently asked questions
What is a patient transfer board?
A rigid, low-friction board placed between table and trolley so the patient can be slid across rather than lifted.
How many staff are needed to move a patient off the operating table?
It depends on the patient, the aids used and local policy. Several staff are normally involved, with one leading and protecting the airway.
Can a table-trolley avoid transfers completely?
It can reduce them, since the patient stays on one surface through the pathway, but clinical needs may still require a move.
Should the transfer board be radiolucent?
If it will remain under the patient during imaging, yes. Check the specification with the supplier.
Related articles
- How to Choose Operating Tables for Surgery in a UAE Hospital
- Operating Room Tables for Sale in the UAE: Budget Guide
- Choosing a Bariatric Operating Room Table for Obesity Surgery
- Choosing an Operating Table for Plastic and Aesthetic Surgery Clinics
- OT Table With Ortho Attachment: Turning a Standard Table Into a Fracture Table
- Procedure room vs operating room: how planners separate the two
- Selecting an Orthopedic Operating Table for Trauma and Joint Surgery
- Radiolucent Operating Table for C-Arm and Fluoroscopy
- Ophthalmic Surgery Table: What Eye Theatres Need
- Surgical Light with Video Camera: Options, Image Quality and Planning Points
- Choosing a medical equipment supplier in the UAE: a buyer's checklist
- Operating room video integration: routing endoscopy, cameras and PACS to every screen