The A.R.C. FOX IV 810 is a portable 810 nm diode laser for ophthalmology that runs from battery or mains and weighs just 1.53 kg. This overview covers its power and pulse range, micropulse cyclophotocoagulation functions, transcanalicular DCR capability and LIO compatibility, and gives UAE eye hospitals criteria for comparing any portable ophthalmic diode laser, whichever manufacturer they consider.
Key specifications
FOX IV 810 is a diode laser at 810 nm with 8 W output power in a metal housing. Pulse length ranges from 100 µs to 60 s or continuous wave. It measures 17.4 × 14.2 × 16.3 cm and is supplied with its accessories in a carrying case.
A large colour touch display shows the key parameters in the central field of view, with application-specific colour schemes, so the operator can confirm settings quickly in a dim room or theatre.
The compact housing and carrying case make the laser easy to move between a clinic room, a ward and an operating theatre, and the battery means it can be used where a mains outlet is not close to the patient.
- Wavelength 810 nm, output power 8 W.
- Pulse length 100 µs to 60 s or CW.
- Weight 1.53 kg, battery or mains operation.
- Power limit of 3 W for glaucoma and retinal treatments.
Micropulse cyclophotocoagulation functions
For micropulse cyclophotocoagulation (µCPC) the laser offers energy and time counters, voice output every 10 s or 10 J and a metronome signal every 1 s or 1 J. These aids help the surgeon keep a consistent sweeping rhythm without watching the display. The geometry of the direction-independent µCPC probe tip is protected by patents in Germany, Europe and the USA, according to the manufacturer.
For the broader clinical background see our articles on diode laser cyclophotocoagulation and the micropulse laser explainer; this page covers the equipment.
TCL-DCR, LIO and retinal use
With 8 W the laser also has power to open bony structures in transcanalicular dacryocystorhinostomy (TCL-DCR), and it has a dedicated function for it. Details are in our article on laser dacryocystorhinostomy.
Coupled to the LIO indirect ophthalmoscope through the click-plug system, the FOX 810 supports mobile retinal photocoagulation, including treatment of retinopathy of prematurity, independent of a slit lamp. See ROP laser equipment for the neonatal setting.
Whatever the application, keep a record of settings and delivered energy for each case. The built-in counters make this simpler.
Portable ophthalmic diode laser: how to compare
When comparing portable diode lasers from any manufacturer, ask for documented output stability, battery runtime under typical loads, charging time, probe and fibre costs, display readability and the training provided. Ask for hands-on use with your own probes and workflows. We do not quote other manufacturers' specifications here.
Consider also how many services share the laser. A single portable unit that serves glaucoma, retina and oculoplastics lists can be well utilised, but only if scheduling, probe stock and sterilisation routines are organised. See the ophthalmic laser buying guide and types of ophthalmic lasers.
If several departments will share one laser, agree who owns it, where it is stored and charged and how probes and fibres are tracked, otherwise a portable device can easily go missing or be left uncharged.
Safety, service and next steps
Even a small laser requires full laser safety measures: controlled access, wavelength-specific eyewear, trained operators and a log. Our medical laser safety guide outlines them. Agree on a service and calibration path in the UAE before purchase, since a portable laser that travels between sites is exposed to more handling.
Beckfinity can arrange a FOX IV 810 demonstration for your glaucoma, retina or oculoplastic team. Contact our specialists for a quote and confirm current registration requirements with the relevant UAE authorities.
Frequently asked questions
How much does the FOX IV 810 weigh?
1.53 kg according to A.R.C. Laser, with battery or mains operation.
What is µCPC?
Micropulse cyclophotocoagulation, a glaucoma procedure that uses an 810 nm diode laser delivered through a probe. The FOX IV 810 has dedicated counters and voice and metronome aids for it.
Can it be used for dacryocystorhinostomy?
Yes. With 8 W it can open bony structures in TCL-DCR and has a dedicated function.
Is it compatible with an indirect ophthalmoscope?
Yes. The A.R.C. LIO connects through a click-plug system for mobile retinal photocoagulation.
Related articles
- Medical Laser Safety Guidelines for Hospitals and Clinics
- The Medical Laser Safety Officer: Duties, Training and Certification
- Retinal Photocoagulation Laser: Wavelengths, Delivery and Selection
- A.R.C. Laser Portfolio Explained for UAE Hospital Buyers
- YAG SLT Combo Laser: the A.R.C. COBRA Workstation
- PCL5 Slit Lamp: Specifications and Configurations
- CO2 DUO3 Laser Concept: Two Wavelengths for ENT Surgery
- Q-Las YAG Laser: Capsulotomy and Iridotomy Workstation
- A.R.C. CLASSIC 514: a Compact 514 nm Photocoagulator
- What Is a Mayfield Head Holder in Neurosurgery?
- Medical Gas System Suppliers in the UAE: A Buyer Guide
- Skin graft mesher guide for burn and plastic surgery units