The BOWA SHE SHA smoke evacuator removes surgical smoke at its source, using a four-stage filter with ULPA-15 and activated carbon, automatic sensor activation and low noise. It is designed to work with any electrosurgical unit, which makes it relevant to UAE hospitals that run mixed generator fleets. This article summarises the manufacturer data and the practical points to check before buying.
What the SHE SHA does
SHE SHA is a surgical smoke evacuation system intended to keep operating-theatre air clean by removing the plume where it is produced. Smoke from electrosurgery, lasers and ultrasonic devices contains particles and vapours that staff should not breathe; for background see our overview of surgical smoke hazards.
The unit is compact: 15 × 28 × 39.5 cm (H × W × D) and 4.4 kg, or 5.5 kg with the filter fitted. That makes it easy to place on a trolley, shelf or generator stack without dedicating floor space.
Four-stage filtration
The filter combines a pre-filter, an ULPA-15 stage, activated carbon and a post-filter. BOWA states that it captures particles down to 0.1 µm with 99.999 % efficiency. The pre-filter protects the fine filter from larger debris, while activated carbon addresses odours and gaseous components that particle filters do not retain.
The filter is detected automatically, its remaining life is shown on the display, and the manufacturer quotes a life of up to 35 hours of activation. This matters for planning: you can estimate replacement intervals from theatre use. For more on filter types and tubing see our guide to smoke evacuator filters.
- Pre-filter, ULPA-15, activated carbon and post-filter
- 99.999 % efficiency for particles down to 0.1 µm
- Automatic filter detection and remaining-life display
- Up to 35 hours of activation per filter
Airflow, noise and activation
Maximum flow is 708 l/min with a 22 mm hose, with three suction levels to match the procedure. Noise is stated as a maximum of 55 dBA, which is important in theatres where the team must communicate clearly and where an evacuator running for hours can become a distraction.
A universal sensor switches the unit on only when smoke is produced, so it works with any electrosurgical device without wiring. A footswitch allows manual activation, and with BOWA ARC generators activation can run via a connecting cable. Sensor-based activation is convenient, but verify in a demonstration that it responds reliably with the pencils and generators you actually use.
Accessories for open and laparoscopic work
The system is completed by single-use smoke evacuation handles and laparoscopy hoses. In open surgery a handle or a nozzle held near the site captures the plume; in laparoscopy a hose connects to a filtered port or the insufflation circuit. Our article on smoke evacuation in laparoscopy covers how to preserve pneumoperitoneum while clearing smoke.
When comparing systems, ask which consumables are single-use, what the replacement filter and tubing programme looks like, and how many pencil and handle options are compatible with your generators.
SHE SHA with BOWA ARC and other generators
Because the sensor is generator-independent, SHE SHA can serve alongside the ARC 400, older units from other makers, or monopolar pencils used in minor-procedure rooms. Where you also consider alternatives, such as the ATMOS MEDAP FUMOVAC 700 with 700 l/min, compare them on measurable criteria: flow at the tip, filter efficiency, noise, filter life, size and how activation is triggered.
Buying and installation notes
Plan where the unit will sit, how long the hose runs, and who changes filters. Train staff to place the nozzle within a few centimetres of the source and to replace the filter when the unit signals it. Beckfinity can supply the system and arrange installation and training; contact our specialists for a quote.
Frequently asked questions
What filtration does the BOWA SHE SHA offer?
A four-stage filter with pre-filter, ULPA-15, activated carbon and post-filter, stated to capture particles down to 0.1 µm with 99.999 % efficiency.
Does it work with any electrosurgical unit?
Yes, a universal sensor activates it when smoke is produced, so it works with any electrosurgical device. A footswitch gives manual control.
How long does a filter last?
BOWA states up to 35 hours of activation, with remaining life displayed on the unit.
How loud is it?
The stated noise level is a maximum of 55 dBA.
Related articles
- Electrosurgical Unit Uses: What an ESU Does Across Surgical Specialties
- Monopolar vs Bipolar Electrosurgery: Which Mode for Which Task?
- Smoke Evacuator Guide: Choosing a Surgical Smoke Evacuation System
- How to choose a diathermy machine for minor operations in a clinic
- BOWA ERGOseal Vessel Sealing Instrument: Workflow and Requirements
- Parts of Diathermy Machine Explained: From Generator to Footswitch
- Laparoscopic Bipolar Forceps with Finger Switch: BOWA ERGOact
- How to Use a Diathermy Machine: Setting Power Safely
- BOWA electronic GmbH & Co. KG: company profile and product range
- Neurosurgery instruments: the core hand tools and what each one does
- Flexible Ureteroscopy Step by Step: The Equipment at Each Stage
- Portable X-Ray Machine Price in the UAE: Budgeting Factors for Buyers